Open the list of currently defined assays by selecting (Admin) > Manage Assays. Click on the name of any assay to open the runs page. The Manage Assay Design menu provides the following options:
Fields in an assay design can support defining default values using the field editor. Defaults can be of several types: last entered, editable default, and a fixed value.
Values for editable and fixed value properties are then set using the Set Default Values option on the Manage Assay Design menu. The assay design may be then be inherited in subfolders, which may override these parent defaults if needed using the Set Default Values option in the other container. These folder defaults will, in turn, be inherited by sub-folders that do not specify their own defaults. You can set defaults for:
Some assays, like the Standard assay type, allow you to make run and data rows editable individually. Editability at the run or result level is enabled in the assay design by an administrator. Any edits are audited, with values before and after the change being captured. See the audit log's Assay/Experiment events. Upon deleting assay data, the audit log records that a deletion has occurred, but does not record what data was deleted.
Some assay types, including Standard and Luminex, allow you to upload a replacement copy of a file/run. This process is called "re-import" of assay data. The server retains the previous copy and the new one, allowing you to review any differences.
See the Assay Feature Matrix for details about which assay types support editable runs/results and re-import.